Development of an advanced micro-positioning system for increasing operation accuracy

Consideration of high pressure sealing

verfasst von
Sabrina Pluemer, Kathrin Voges-Schwieger, Berend Denkena, Bernd Arno Behrens
Abstract

This paper presents the development of a micro-positioning system for the increase of operation accuracy of machine tools. A highly dynamic piezo-actuated micropump coupled with a hydraulic cylinder transforms small strokes of the piezoelectric actuator into a continuous piston movement. Fast-switching active valves direct the volume flow. Crucial for the functionality of the pump module is the sealing function of the membrane to isolate the piezoelectric actuator unit against high pressure fluid. Therefore, the requirements for foil membrane selection are investigated by means of a developed test bench. It is demonstrated that a successful test of foil membrane materials provides a closer insight into the entire valve characteristics.

Organisationseinheit(en)
Institut für Fertigungstechnik und Werkzeugmaschinen
Institut für Umformtechnik und Umformmaschinen
Typ
Artikel
Journal
Production Engineering
Band
6
Seiten
213-218
Anzahl der Seiten
6
ISSN
0944-6524
Publikationsdatum
17.01.2012
Publikationsstatus
Veröffentlicht
Peer-reviewed
Ja
ASJC Scopus Sachgebiete
Maschinenbau, Wirtschaftsingenieurwesen und Fertigungstechnik
Elektronische Version(en)
https://doi.org/10.1007/s11740-012-0361-2 (Zugang: Unbekannt)
 

Details im Forschungsportal „Research@Leibniz University“