Development of an advanced micro-positioning system for increasing operation accuracy

Consideration of high pressure sealing

authored by
Sabrina Pluemer, Kathrin Voges-Schwieger, Berend Denkena, Bernd Arno Behrens
Abstract

This paper presents the development of a micro-positioning system for the increase of operation accuracy of machine tools. A highly dynamic piezo-actuated micropump coupled with a hydraulic cylinder transforms small strokes of the piezoelectric actuator into a continuous piston movement. Fast-switching active valves direct the volume flow. Crucial for the functionality of the pump module is the sealing function of the membrane to isolate the piezoelectric actuator unit against high pressure fluid. Therefore, the requirements for foil membrane selection are investigated by means of a developed test bench. It is demonstrated that a successful test of foil membrane materials provides a closer insight into the entire valve characteristics.

Organisation(s)
Institute of Production Engineering and Machine Tools
Institute of Metal Forming and Metal Forming Machines
Type
Article
Journal
Production Engineering
Volume
6
Pages
213-218
No. of pages
6
ISSN
0944-6524
Publication date
17.01.2012
Publication status
Published
Peer reviewed
Yes
ASJC Scopus subject areas
Mechanical Engineering, Industrial and Manufacturing Engineering
Electronic version(s)
https://doi.org/10.1007/s11740-012-0361-2 (Access: Unknown)
 

Details in the research portal "Research@Leibniz University"